How to Measure Shock Current

Step 1: Set Shock Level

Set shock level, say 0.7mA

Step 2: Start Treadmill Run

  1. Click on Start button on the control screen to start treadmill
  2. Push red buttons on treadmill to start counting
  3. Click Electric button on the control screen to start shocks

The treadmill is running with shock on.

Step 3: Measure Current Level

  1. Turn on a voltage meter as shown below (in AD mode)
  2. Touch point needles to adjacent grid bars and read the meter measurement (0.69 mA)
  3. The error should be within 0.10mA

Was this article helpful?

Products Featured in This Article

Related Articles

Treadmill User Manual

This manual covers the safety precautions, key features, and operation of a treadmill designed for animal exercise testing, including specifications for its LCD monitor, servo motor, speed control, data recording, electric stimulus capabilities, and individual lane counting functionality.

Treadmill Air Puff Manual

This manual covers the components, assembly, and software configuration of the Treadmill Air Puff system, which delivers air stimuli to animals on a treadmill through an air compressor, solenoid box, and tubing network controlled by a software interface.

Treadmill Q_A

This Q&A document addresses common questions about a research treadmill system for laboratory animals, covering topics including control interface, programmable sessions, compatibility with mice and rats, lane configuration options, and shipping information.

Treadmill support setup manual

This manual provides instructions for assembling a treadmill support system, covering the installation of setup posts, horizontal bar, balance levers, and body holder components. The document guides users through each assembly step with specific fastening and positioning requirements.

Treadmill Specification

This specification document describes the technical features of the Maze Engineers Treadmill, a laboratory apparatus available in 1-5 lane configurations designed for both rat and mouse testing, with adjustable speed (1-100 m/min), slope (±35°), and stimulus parameters. The system includes independent lane control, real-time monitoring of distance, duration, shock count, and animal state via a capacitive touch screen interface.

Need more help?

Our support team is here to assist you