Product Documentation

Setup guides, software manuals, and specifications for ConductScience products

Camera

Software documentation for Camera

No articles yet

ConductVision

Software documentation for ConductVision

Conduct Vision Fear Conditioning Software Manual

This manual covers the installation, configuration, and operation of ConductVision Fear Conditioning Software, a GPU-based application used to conduct fear conditioning experiments with maze types and video tracking capabilities. The documentation includes instructions for software setup, experiment configuration, stimulus protocol management, hardware adapter integration, and data analysis features.

Conduct Vision Fish Software Manual

This manual covers the installation, configuration, and operation of Conduct Vision Fish Software, which is used to run behavioral experiments on fish with features including maze selection, video tracking, social interaction analysis, and multi-animal tracking. The software supports multiple maze types (FishOpen, Y-Maze, T-Maze, Mirror Biting) and provides tools for experiment configuration, data analysis, and export.

Conduct Vision Homecage System Specification

This specification document describes the Conduct Vision Home Cage System, which includes 140 mouse cages housed in stainless steel racks with integrated NVIDIA Jetson Orin Nano-based monitoring devices, along with a server computer running Conduct Vision software for behavior analysis and optional cloud-based remote monitoring capabilities.

ConductVision Y-maze protocol

This document describes the ConductVision Y-maze protocol, which provides software analysis of spontaneous alternation behavior in rodents to assess spatial memory and exploratory behavior. The protocol details how to specify Y-maze arm entry sequences, calculate alternation results, and interpret alternation percentages as indicators of working memory and cognitive function.

ConductVision Catwalk Specification

This specification document describes the ConductVision Catwalk system, a gait analysis device consisting of a glass walkway platform with LED illumination and high-speed camera hardware that captures rodent paw contacts, paired with AI-powered software that automatically detects and analyzes spatial, temporal, kinetic, and coordination parameters of animal gait. The system measures various metrics including stride length, stance time, paw pressure, and limb coordination patterns.

Camera Specification

This document specifies the technical parameters for two Conduct Vision infrared camera models: the Standard HD IR Camera with 2-megapixel resolution and 30 fps frame rate, and the Advanced HD IR Camera with 5-megapixel resolution and 60 fps frame rate. Both cameras feature CMOS sensors, multiple field of view options, and MJPG format output with USB connectivity.

Conduct Vision Fly Software Manual

This manual covers the installation, configuration, and operation of Conduct Vision Fly Software, which is used to conduct behavioral experiments with flies including maze-based tasks, video tracking, multi-animal social interaction analysis, and marker-less tracking. The manual provides instructions for setting up the application, configuring experiment protocols, connecting video services, running experiments, and exporting experimental data.

Conduct Vision Software Manual

ConductVision Software Manual Contents 1\. Install and Run Application 7

Conduct Vision Social Interaction Software Manual

This manual covers the installation, configuration, and operation of Conduct Vision Social Interaction Software, which is used for conducting behavioral experiments with animals in various maze types and analyzing social interaction behaviors through video tracking and data analysis.

Camera Manual

This manual covers the Conduct Vision Camera, including instructions for connecting the camera to a PC, mounting options using a camera holder, and software setup using the built-in Camera app on Microsoft Windows devices.

ConductVision Specification

This specification document describes ConductVision, an AI-powered animal behavior tracking software that operates at 30+ frames per second and supports multiple behavioral paradigms for tracking mice, rats, ferrets, zebrafish, and drosophila. The document details the software's key features, advantages, and hardware requirements for Windows computers and compatible cameras.

Data Visualizations

This document describes data visualization types for mouse movement analysis, including 2D density heatmaps of spatial position, trajectory paths, cumulative distance tracking for individual body parts, and distributions of distances between body part pairs.

Rotarod

Setup guides and manuals for the Rotarod

RotaRod Hardware Manual

This manual provides instructions for the RotaRod hardware, a laboratory instrument used for animal behavioral testing that features a rotating rod with individual lane monitoring, LCD touchscreen controls, servo motor operation, and data recording capabilities. The document covers general safety precautions, key product features including multi-step speed control and experiment data management, system connections, and basic operation instructions.

Rotarod Specification

This document provides the technical specifications for a Rotarod apparatus, an animal behavioral testing device used for rat and mouse motor coordination assessments, detailing physical dimensions, lane configurations, control system interface, speed parameters, and fall detection capabilities.

RotaRod Software Manual

This manual covers the installation, setup, and operation of RotaRod Software, including application installation requirements, connecting the RotaRod device to a computer via USB cable, and collecting and exporting experimental data to Excel format.

5 min to 40 rpm setup

This document provides setup instructions for configuring a rotarod apparatus to accelerate from 4 rpm to approximately 40 rpm over a 5-minute period, including the required acceleration parameter settings. Reference files with visual guides are provided to assist with the configuration process.

RotaRod Motor Replacement Instruction

This instruction manual provides step-by-step procedures for replacing the motor in a RotaRod device, including removing the motor cover, disconnecting the old motor, connecting the new motor, and reassembling the unit.

Sleep Deprivation Chamber

Setup guides and manuals for the Sleep Deprivation Chamber

Treadmill

Setup guides and manuals for the Treadmill

Treadmill User Manual

This manual covers the safety precautions, key features, and operation of a treadmill designed for animal exercise testing, including specifications for its LCD monitor, servo motor, speed control, data recording, electric stimulus capabilities, and individual lane counting functionality.

Treadmill Q_A

This Q&A document addresses common questions about a research treadmill system for laboratory animals, covering topics including control interface, programmable sessions, compatibility with mice and rats, lane configuration options, and shipping information.

Treadmill Air Puff Manual

This manual covers the components, assembly, and software configuration of the Treadmill Air Puff system, which delivers air stimuli to animals on a treadmill through an air compressor, solenoid box, and tubing network controlled by a software interface.

Treadmill support setup manual

This manual provides instructions for assembling a treadmill support system, covering the installation of setup posts, horizontal bar, balance levers, and body holder components. The document guides users through each assembly step with specific fastening and positioning requirements.

How to Measure Shock Current

This manual provides instructions for measuring shock current on a treadmill equipped with an electric shock system, including steps for setting the shock level, starting the treadmill with shocks activated, and using a voltage meter to verify the current measurement is within acceptable tolerance.

Treadmill Specification

This specification document describes the technical features of the Maze Engineers Treadmill, a laboratory apparatus available in 1-5 lane configurations designed for both rat and mouse testing, with adjustable speed (1-100 m/min), slope (±35°), and stimulus parameters. The system includes independent lane control, real-time monitoring of distance, duration, shock count, and animal state via a capacitive touch screen interface.

Metabolic Treadmill

This manual covers the Metabolic Treadmill, a sealed animal treadmill designed to integrate with metabolic measurement systems, and describes its connectors, air inlet/outlet configuration, and physical specifications.

Treadmill Integration with Metabolism

This document describes the sealing, ventilation, connector specifications, and key dimensional features of a treadmill designed for metabolic integration studies. The treadmill includes front air inlet and back air outlet ventilation ports and uses 2mm or 4mm male connectors.

Treadmill Software Manual

This manual covers the installation and operation of treadmill software, including application setup, USB connection to a computer via COM port, and procedures for collecting and exporting exercise data to Excel files.

Adjust space between grid and belt

This section of the manual provides instructions for adjusting the spacing between the grids and belt on the device by loosening screws, inserting acrylic U-shaped spacer pieces into designated slots, and then retightening the screws.